T&R 200A 3PH Mk2 Three Phase System Description

The T&R 200A 3PH Mk2 three phase system is the ideal tool for commissioning and maintenance engineers. It allows current injections of up to 200A, and the outputs have fuse protection in order to ensure your safety. Furthermore, the device features a timing system, which allows for highly accurate trip time measurements. All of this comes in a clean, compact layout that is easy to use, even for those with little previous experience. We offer the 200A 3PH Mk2 three phase system to rent for as little as £190 per week.

Features and Benefits

  • Accurate true RMS digital metering (200A-3PH/ED)
  • Accurate true RMS analogue metering (200A-3PH/E)
  • All outputs fully isolated
  • Multi-function 1ms resolution timing system
  • Auxiliary AC output

Product Specs

  • Main Output: Range: 5V, Continuous: 50A, 5 minutes: 100A, 1 minute: 200A
  • Auxiliary AC Outputs: A switched, isolated auxiliary 240V 50mA AC supply is available to power auxiliary control circuits. The output has fuse protection
  • Supply Requirements: 400V+14%-6%,  50/60Hz 3ph 4 wire 3300VA max. A delta-star transformer is available as an optional accessory for operation from a 3 wire supply
  • Temperature Range: Storage -20°C to 60°C, Operating: 0°C to 45°C
  • Dimensions: 315mm x 550mm x 300mm
  • Weight: 35kg
  • Accessories: Operating manual, mains lead, spare fuse set
  • Timing System: Range: 0-999.999s, Resolution: 1ms, Accuracy: 0.01% rdg +1d (all except current operated mode), 0.01% rdg +3d (current operated mode). The contact circuit has an open circuit voltage of 24Vdc and a short circuit current of 300mA. You can connect the contacts to volt-free contacts or contacts connected to a DC voltage system (220Vdc maximum)
  • Protection and Safety: The device has electronic over current trip protection on the outputs, fuses on the contact input, the mains input and regulators. It also features fuses on the contact input, the mains input and regulators. The auxiliary AC output has fuse protection on both units. An earth terminal is provided for connection to a local earth. The unit is designed to comply with BSEN61010, and is CE marked.
  • Optional Lead Set specifications: The unit lead set includes the following items: 6 x 5m 25mm2 200A leads terminated in M10 fork crimps, 1 x 5m 2 core auxiliary lead terminated in 4mm plugs, 1 x 5m 2 core auxiliary lead terminated bare ends. The lead set is supplied in a reinforced plastic wallet